AUTOCLAVED AERATED CONCRETE PANEL(AAC)Is the porous concrete, which composed of quartz sand, aluminum, lime, etc. as the main raw material, ...

PRODUCT DESCRIPTION

1. Light weight: Bulk density 425~625kg/m³, Only for 1/4 concrete, 1/3 Clay brick, The weight of the building can be greatly reduced, and the design value is reduced too.

2. Fire resistance: 125mm AAC panel fire resistance can reach more than 4 hours, It is real fire prevention material in Grade A.50mm AAC panel can be met the fire protection requirements of steel structural members.

3. Anti crack: The shrinkage value of natural state is smaller than that of the clay brick, and the special technology is adopted to solve the problem of the quality of the slab cracks.

4. Thermal insulation: thermal insulation is only 0.11(B04), It is a new type of building material that can meet the building energy saving more than 65% by a single wall.

5. Seismic resistance: Allowable inter layer deflection angle 1/150, When the special node is used to achieve 1/120, In the case of all the nodes, the panel will not fall off when the 1/20 is changed in the layer;So that the anti-seismic effect is excellent.

6. Environmental protection: No radiation, Both the internal and external illumination coefficient are less than 0.1, is 1/4 of Fly ash board, Excellent sound insulation performance, 100mm AAC panel(Double sides putty)could reach 40.8dB, The sound insulation effect of is similar with 200mm fly ash brick wall.

7. Bearing capacity: The plates are equipped with internal double layers, two-way mesh reinforcement, can produce wall panels, partition wall, floor decking, roof board, decorative board etc..

8. economical: Using AAC board as the wall material, can effectively improve the use of the building area, reduce the use of energy consumption, to achieve the national building energy efficiency standards. Under the same sound insulation and fire protection requirements, AAC plate thickness is the smallest, and don't required the tie column, waist beam and other auxiliary components, This can reduce the wall load, thereby reducing the cost of construction.

9. Extensive: Can be used for concrete structure, steel structure residential buildings, office buildings, building internal and external wall body, floor slab, roof panel, firewall, explosion-proof wall, structural steel beams and columns fire maintenance, soundproof walls, old buildings and renovation.

10. Convenience: Eliminating the traditional building blocks in the process of the type of work, such as Mixing, masonry, plastering, reinforcement, formwork and concrete etc. Just the plate installation workers can do all the work, Avoid the conflict of work and mutual restraint.


Performance Indices in Grade B05
ItemUnitDetection valueTest standardStandard
value
Dry bulk densitykg/m³512GB/T11970-1997±50
Cube compressive strength (average)Mpa≥4.0GB/T11971-1997≥2.5
Drying shrinkagemm/m0.48GB/T11972-1997≤0.8
Coefficient of thermal conductivity (water content 5%)W/m.k0.11GB/T10295-2008≤0.14
Frost
resistance
mass loss%1GB/T11973-1997≤5.0
Post freezing strengthMpa≥2.0≥2.0
Impact resistance (30kg sand pendulum impact back without crack)times≥7.0JC666-19973
The single point hanging forceN1200(100mm AAC)JC666-1997≥800
1500(125mm AAC)
Bond strength between steel bar and AAC panelMpaaverage value 2.4GB/T15762-2008≥1.0
Fire resistance limit of AAC platehour100mm wall: 3.62
125mm wall: >4.0
GB/T9978-2008
Protective steel column fire resistance limit in 50mm AAC panel hour>4.0GB/T9978-20084
Protective steel beam fire resistance limit in 51mm AAC panel hour>3.0GB/T9978-20083
Water softening coefficient R/R%0.88GB/T11970-1997
Average
sound
insulation
100mm AAC panel+Both sides puttydB41.8GBJ75-84
GBJ121-88

125mm AAC panel+Both sides putty45.1
150mm AAC panel+Both sides putty46.6
175mm AAC panel+Both sides putty48.1
200mm AAC panel+Both sides putty51.3
Combination form-1(Both sides rock wool & AAC panel inside)150mm+40mm rock wool in both sides+10mm gypsum board(decoration)+Both sides putty55.2
Combination form-2(Both sides AAC panel & rock wool inside)100mm AAC+50mm rock wool+100mm AAC
+Both sides putty
58.6
Dimension errormmL±3
W+0~2
T±1
GB/T15762-2008L±4
W+0~4
T±2
Surface smoothnessmm1GB/T15762-2008≤3
Linear expansion coefficient/℃7x10

Elastic modulusN/mm1.75x10

Permeability (6 days 300mm high water spout drop height)mm88.3
(Contrast test of standard red brick fell 283.3mm in 4 days)
refer to JISA5416-1997≤100


Fire performance index of AAC inner wall plate
Wall thickness(mm)5075100125150
Fire resistance time(hour)1.57>23.62>4>4


Specification of AAC inner wall plate
Thickness(mm)75100125≥150
Length(mm)≤3000≤4000≤5000≤6000


Specification of AAC external wall plate
                            Thickness
       Length max.        (mm)
                        (mm)
Design load
100125150175200
1.2KN/㎡36004200520060006000
1.4KN/㎡35004200490060006000
1.6KN/㎡33004000470057006000
1.8KN/㎡31003900450054006000
2.0KN/㎡30003800430052006000
2.2KN/㎡28003600420050005800
2.3KN/㎡27003400410047005600


Specification of AAC Roof plate
                            Thickness
       Length max.        (mm)
                        (mm)
Design load
100125150175200
1.4KN/㎡26003100370046005600
1.6KN/㎡25002900360044005400
1.8KN/㎡24002700350042005100
2.0KN/㎡23002500330040004800
2.2KN/㎡22002300320038004500
2.4KN/㎡21002300310036004200
2.6KN/㎡20002300300034003900


Thermal insulation performance of AAC external wall plate
ThicknessThermal resistancethermal inertia indexheat transfer resistanceheat transfer coefficient
δ(mm)R(㎡.k/W)D=∑RSR0(㎡.k/W)k(W/㎡.k)
500.310.920.462.17
750.451.310.601.67
1000.591.690.741.35
1250.722.070.871.15
1500.862.451.010.99
1751.002.831.150.87
2001.143.221.290.78


Thermal insulation performance of AAC roof plate
ThicknessThermal resistancethermal inertia indexheat transfer resistanceheat transfer coefficient
δ(mm)R(㎡.k/W)D=∑RSR0(㎡.k/W)k(W/㎡.k)
1500.812.280.961.04
1750.933.201.080.93
2001.053.591.200.83
2251.173.971.320.76
2501.294.361.440.69